2-Ply Depth-Loading Panel & Link Filters

This 2-ply synthetic media uses a depth-loading structure designed to capture larger particles in the first layer and progressively smaller particles through the downstream layer. Compared with surface-loading media, depth-loading reduces the rate of resistance increase, supporting lower energy use and longer service life.

  • Helps eliminate bypass between adjacent filters
  • Keeps coils cleaner to maintain system efficiency
  • Supports energy savings via lower resistance rise
  • Resistant to moisture and mold
  • Reduced filter failure risk; no paperboard components
  • MERV 6 (per ASHRAE 52.2-2017)

Construction & Application Notes

  • Media: Two deniers of synthetic fibers for progressive depth loading
  • Support: Internal galvanized wire ring sealed between media layers
  • No frame gap in link configurations to minimize bypass
  • Continuous operating temperature: 200 °F
  • Meets ANSI/UL-900 requirements
  • Special sizes available
  • Width and height are interchangeable; actual size reflects internal wire support (minimum 1/2" perimeter selvedge)
  • Options: Antimicrobial treatment, link configuration, roll-up configuration

Performance Data — Link Filters

Nominal Size (H×W) # Panels Panel Size Airflow 300 FPM (CFM) Airflow 500 FPM (CFM) Airflow 625 FPM (CFM)
12 × 48212 × 24120020002500
12 × 72312 × 24180030003750
15 × 40215 × 20125120852606
15 × 48215 × 24150025003125
15 × 60315 × 20187531253906
16 × 32216 × 16108018002250
16 × 36216 × 18120020002500
16 × 40216 × 20132022002750
18 × 32218 × 16120020002500
18 × 48218 × 24180030003750
18 × 64418 × 16240040005000
20 × 30220 × 15125120852606
20 × 32220 × 16132022002750
20 × 40220 × 20166527753469
20 × 45320 × 15187531253906
24 × 30224 × 15150025003125
24 × 32224 × 16159026503313
24 × 36224 × 18180030003750
24 × 40224 × 20201033504188
24 × 45324 × 15225037504688
25 × 32225 × 16166527753469
25 × 40225 × 20207034504313
25 × 48325 × 16249041505188
25 × 50225 × 25261043505438
25 × 60325 × 20312052006500

Performance Data — Panel Filters

Nominal Size (H×W) Actual H (in) Actual W (in) Airflow 300 FPM (CFM) Airflow 500 FPM (CFM) Airflow 625 FPM (CFM)
12 × 2411¼23¼60010001250
15 × 2014¼19¼62510421302
15 × 2414¼23¼75012501563
16 × 1615¼15¼5409001125
16 × 1815¼17¼60010001250
16 × 2015¼19¼66011001375
16 × 2415¼23¼81013501688
16 × 2515¼24¼84014001750
18 × 2417¼23¼90015001875
20 × 2019¼19¼84014001750
20 × 2419¼23¼99016502063
20 × 2519¼24¼104117352169
24 × 2423¼23¼120020002500
25 × 2524¼24¼130221702713

Specifications

MediaSynthetic, two-denier progressive depth-loading
Support/Frame9½-gauge galvanized internal wire ring (sealed between media layers)
Final Resistance1.0" w.g.
EfficiencyMERV 6 (ASHRAE 52.2-2017)
Operating Temp (Continuous)200 °F
StandardsMeets ANSI/UL-900
Available OptionsAntimicrobial treatment; link configuration; roll-up configuration

Good Practices

  • Use link filters where eliminating gaps between adjacent filters is critical.
  • Verify sizing: nominal vs. actual dimensions may differ due to internal support.
  • Replace based on pressure drop and application requirements to maximize energy savings.

This economical 2-ply panel and link filter is designed as an upgrade and replacement for traditional fiberglass disposable filters. It provides a cost-effective option where reliable filtration is required.

The selvedge edge of the panel and link filter creates a seal that eliminates bypass of unfiltered air – a common problem with cardboard-framed filters. Unlike cardboard, these filters resist moisture and mold, reducing the risk of damage, collapse, or microbial growth within HVAC systems. Available as both ring panels and links in standard and custom sizes.

Key Features

  • Cost-effective with consistent performance
  • Eliminates dirty air bypass
  • Moisture resistant
  • Mold resistant
  • Available in custom sizes
  • Internal wire support for strength
  • Fits side, front, or rear access housings
  • Lower shipping and storage costs
  • Reduced handling damage

Construction & Application Notes

The selvedge edge of each panel and link filter is engineered to seal tightly within housings, helping eliminate unfiltered air leakage. Panels are suitable for a wide range of HVAC applications requiring reliable, moisture-resistant performance.

Performance Data

Media 2-ply polyester
Recommended Air Flow 300 FPM (1.5 m/sec)
Initial Resistance 0.22 in. w.g. @ 300 FPM (55 Pa @ 1.5 m/sec)
Recommended Final Resistance 1.0 in. w.g. (250 Pa)
Efficiency MERV 6


2‑Ply Panels, Links & Cubes

High‑loft polyester media arranged in two graduated layers (coarse → fine) for depth loading and longer life. Panels are heat‑sealed around an internal galvanized wire frame and feature a self‑gasketing perimeter to reduce air bypass. Linkable panels can simplify handling and reduce change‑out time.

Series & Performance

Series Construction Tackifier Typical Application MERV Initial Resistance @ 300 FPM (in. w.g.)
612‑ply polyNoneLight commercial & industrial HVAC50.15
6102‑ply polyLight, non‑migrating tackifier (downstream of final ply)Light commercial & industrial HVAC70.17
6152‑ply polyInternal, non‑migrating wet tackifier (downstream of 1st ply)Light commercial & industrial HVAC80.22

Key Features

  • Two graduated layers for efficient depth loading
  • Heat‑sealed media around internal galvanized wire frame
  • Self‑gasketing perimeter helps prevent air bypass
  • Panels link together; many sizes available
  • Suitable as pre‑filters or stand‑alone where appropriate
  • Media unaffected by moisture and most HVAC conditions
  • Max continuous operating temperature: 120 °F

Common Uses

  • Manufacturing & distribution
  • Office & retail
  • Government & education facilities
  • Hotels & airports
  • Primary or secondary filtration in HVAC systems