This 2-ply synthetic media uses a depth-loading structure designed to capture larger particles in the first layer and progressively smaller particles through the downstream layer. Compared with surface-loading media, depth-loading reduces the rate of resistance increase, supporting lower energy use and longer service life.
- Helps eliminate bypass between adjacent filters
- Keeps coils cleaner to maintain system efficiency
- Supports energy savings via lower resistance rise
- Resistant to moisture and mold
- Reduced filter failure risk; no paperboard components
- MERV 6 (per ASHRAE 52.2-2017)
Construction & Application Notes
- Media: Two deniers of synthetic fibers for progressive depth loading
- Support: Internal galvanized wire ring sealed between media layers
- No frame gap in link configurations to minimize bypass
- Continuous operating temperature: 200 °F
- Meets ANSI/UL-900 requirements
- Special sizes available
- Width and height are interchangeable; actual size reflects internal wire support (minimum 1/2" perimeter selvedge)
- Options: Antimicrobial treatment, link configuration, roll-up configuration
Performance Data — Link Filters
Nominal Size (H×W) | # Panels | Panel Size | Airflow 300 FPM (CFM) | Airflow 500 FPM (CFM) | Airflow 625 FPM (CFM) |
12 × 48 | 2 | 12 × 24 | 1200 | 2000 | 2500 |
12 × 72 | 3 | 12 × 24 | 1800 | 3000 | 3750 |
15 × 40 | 2 | 15 × 20 | 1251 | 2085 | 2606 |
15 × 48 | 2 | 15 × 24 | 1500 | 2500 | 3125 |
15 × 60 | 3 | 15 × 20 | 1875 | 3125 | 3906 |
16 × 32 | 2 | 16 × 16 | 1080 | 1800 | 2250 |
16 × 36 | 2 | 16 × 18 | 1200 | 2000 | 2500 |
16 × 40 | 2 | 16 × 20 | 1320 | 2200 | 2750 |
18 × 32 | 2 | 18 × 16 | 1200 | 2000 | 2500 |
18 × 48 | 2 | 18 × 24 | 1800 | 3000 | 3750 |
18 × 64 | 4 | 18 × 16 | 2400 | 4000 | 5000 |
20 × 30 | 2 | 20 × 15 | 1251 | 2085 | 2606 |
20 × 32 | 2 | 20 × 16 | 1320 | 2200 | 2750 |
20 × 40 | 2 | 20 × 20 | 1665 | 2775 | 3469 |
20 × 45 | 3 | 20 × 15 | 1875 | 3125 | 3906 |
24 × 30 | 2 | 24 × 15 | 1500 | 2500 | 3125 |
24 × 32 | 2 | 24 × 16 | 1590 | 2650 | 3313 |
24 × 36 | 2 | 24 × 18 | 1800 | 3000 | 3750 |
24 × 40 | 2 | 24 × 20 | 2010 | 3350 | 4188 |
24 × 45 | 3 | 24 × 15 | 2250 | 3750 | 4688 |
25 × 32 | 2 | 25 × 16 | 1665 | 2775 | 3469 |
25 × 40 | 2 | 25 × 20 | 2070 | 3450 | 4313 |
25 × 48 | 3 | 25 × 16 | 2490 | 4150 | 5188 |
25 × 50 | 2 | 25 × 25 | 2610 | 4350 | 5438 |
25 × 60 | 3 | 25 × 20 | 3120 | 5200 | 6500 |
Performance Data — Panel Filters
Nominal Size (H×W) | Actual H (in) | Actual W (in) | Airflow 300 FPM (CFM) | Airflow 500 FPM (CFM) | Airflow 625 FPM (CFM) |
12 × 24 | 11¼ | 23¼ | 600 | 1000 | 1250 |
15 × 20 | 14¼ | 19¼ | 625 | 1042 | 1302 |
15 × 24 | 14¼ | 23¼ | 750 | 1250 | 1563 |
16 × 16 | 15¼ | 15¼ | 540 | 900 | 1125 |
16 × 18 | 15¼ | 17¼ | 600 | 1000 | 1250 |
16 × 20 | 15¼ | 19¼ | 660 | 1100 | 1375 |
16 × 24 | 15¼ | 23¼ | 810 | 1350 | 1688 |
16 × 25 | 15¼ | 24¼ | 840 | 1400 | 1750 |
18 × 24 | 17¼ | 23¼ | 900 | 1500 | 1875 |
20 × 20 | 19¼ | 19¼ | 840 | 1400 | 1750 |
20 × 24 | 19¼ | 23¼ | 990 | 1650 | 2063 |
20 × 25 | 19¼ | 24¼ | 1041 | 1735 | 2169 |
24 × 24 | 23¼ | 23¼ | 1200 | 2000 | 2500 |
25 × 25 | 24¼ | 24¼ | 1302 | 2170 | 2713 |
Specifications
Media | Synthetic, two-denier progressive depth-loading |
Support/Frame | 9½-gauge galvanized internal wire ring (sealed between media layers) |
Final Resistance | 1.0" w.g. |
Efficiency | MERV 6 (ASHRAE 52.2-2017) |
Operating Temp (Continuous) | 200 °F |
Standards | Meets ANSI/UL-900 |
Available Options | Antimicrobial treatment; link configuration; roll-up configuration |
Good Practices
- Use link filters where eliminating gaps between adjacent filters is critical.
- Verify sizing: nominal vs. actual dimensions may differ due to internal support.
- Replace based on pressure drop and application requirements to maximize energy savings.
This economical 2-ply panel and link filter is designed as an upgrade and replacement for traditional fiberglass disposable filters. It provides a cost-effective option where reliable filtration is required.
The selvedge edge of the panel and link filter creates a seal that eliminates bypass of unfiltered air – a common problem with cardboard-framed filters. Unlike cardboard, these filters resist moisture and mold, reducing the risk of damage, collapse, or microbial growth within HVAC systems. Available as both ring panels and links in standard and custom sizes.
Key Features
- Cost-effective with consistent performance
- Eliminates dirty air bypass
- Moisture resistant
- Mold resistant
- Available in custom sizes
- Internal wire support for strength
- Fits side, front, or rear access housings
- Lower shipping and storage costs
- Reduced handling damage
Construction & Application Notes
The selvedge edge of each panel and link filter is engineered to seal tightly within housings, helping eliminate unfiltered air leakage. Panels are suitable for a wide range of HVAC applications requiring reliable, moisture-resistant performance.
Performance Data
Media | 2-ply polyester |
Recommended Air Flow | 300 FPM (1.5 m/sec) |
Initial Resistance | 0.22 in. w.g. @ 300 FPM (55 Pa @ 1.5 m/sec) |
Recommended Final Resistance | 1.0 in. w.g. (250 Pa) |
Efficiency | MERV 6 |
2‑Ply Panels, Links & Cubes
High‑loft polyester media arranged in two graduated layers (coarse → fine) for depth loading and longer life. Panels are heat‑sealed around an internal galvanized wire frame and feature a self‑gasketing perimeter to reduce air bypass. Linkable panels can simplify handling and reduce change‑out time.
Series & Performance
Series |
Construction |
Tackifier |
Typical Application |
MERV |
Initial Resistance @ 300 FPM (in. w.g.) |
61 | 2‑ply poly | None | Light commercial & industrial HVAC | 5 | 0.15 |
610 | 2‑ply poly | Light, non‑migrating tackifier (downstream of final ply) | Light commercial & industrial HVAC | 7 | 0.17 |
615 | 2‑ply poly | Internal, non‑migrating wet tackifier (downstream of 1st ply) | Light commercial & industrial HVAC | 8 | 0.22 |
Key Features
- Two graduated layers for efficient depth loading
- Heat‑sealed media around internal galvanized wire frame
- Self‑gasketing perimeter helps prevent air bypass
- Panels link together; many sizes available
- Suitable as pre‑filters or stand‑alone where appropriate
- Media unaffected by moisture and most HVAC conditions
- Max continuous operating temperature: 120 °F
Common Uses
- Manufacturing & distribution
- Office & retail
- Government & education facilities
- Hotels & airports
- Primary or secondary filtration in HVAC systems